Open the tank and inspect the pump

**Only perform this step if you are an authorized service technician.

You will need to separate Vector’s tank from the body for this step. Release the (2) clasps on each side of Vector.

Then, slowly pull the tank approximately 4 inches forward so you can disconnect the (6) cables. There are three on the left side and three on the right side.

Once the cables are disconnected, fully remove the water tank and place it somewhere secure.

To open the tank, unbolt the Fog Chamber from the main tank.

Now, you will be able to access the pump. Verify nothing is blocking the pump intake.

Once you clear any potential blockages, reattach the fog chamber, reconnect the (6) cables, and then secure the tank back into Vector’s body. Then, refill the tank with at least 3 gallons of water and power the system back on.

Once the system is on, turn on the mist feature to verify if the “Pump Alert” code is still active.